Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Dent. press endod ; 10(2): 42-47, maio-ago.2020. Tab, Ilus
Article in English | LILACS | ID: biblio-1344547

ABSTRACT

Objetivo: O objetivo do presente estudo foi avaliar a influência da liga (NiTi convencional e M-Wire) e do movimento (reciprocante e rotação contínua) na resistência à fadiga cíclica. Métodos: Quinze limas Reciproc R25 (VDW GmbH, Munique, Alemanha) foram usadas em movimento reciprocante (MR), enquanto trinta limas Mtwo 25.07 (VDW GmbH, Munique, Alemanha) foram usadas em MR (n=15) ou em rotação contínua (RC) (n=15). Os instrumentos foram submetidos a ensaios dinâmicos movidos por motor elétrico, que permitiram reproduzir o movimento de pecking motion, a 300rpm de velocidade. Os instrumentos simularam a instrumentação de um canal radicular curvo com 40o e 5mm de raio de curvatura. A fratura dos instrumentos foi detectada por um sensor digital, e o tempo e o número de ciclos foram registrados. Os dados foram analisados estatisticamente pelos testes ANOVA e de Tukey (p<0,05). Resultados: Os instrumentos Reciproc R25 movidos por MR alcançaram número significativamente maior (p<0,05) de ciclos antes da fratura (1.777,68±334,2 ciclos), quando comparados aos instrumentos MT 25.07 movidos por MR (610,67±126,3 ciclos) ou RC (432,23±183,2 ciclos). Conclusões: O movimento reciprocante mostrou resistência à fadiga cíclica significativamente maior, e os instrumentos de NiTi M-Wire apresentaram maior resistência à fadiga cíclica do que os instrumentos rotatórios de NiTi convencional (AU).


Objective: The aim of present study was to evaluate the influence of alloy (conventional NiTi and M-Wire NiTi) and movement (reciprocating movement and continuous rotation) on resistance to cyclic fatigue. Methods: Fifteen Reciproc R25 files (VDW GmbH, Munich, Germany) were used in reciprocation motion (RM), while thirty MTwo 25/.07 files (VDW GmbH, Munich, Germany) were used either in RM (n=15) or in continuous rotation (CR) (n=15). The files were submitted to dynamic assays device moved by electric engine that allowed the reproduction of pecking motion under 300 rpm of speed. The files act simulating the instrumentation of a curved root canal with 40º and 5-mm of curvature radius. The fracture was detected by the device sensor and the time and number of cycles were obtained. Data were statistically analyzed by ANOVA and Tukeys tests (p<0.05). Results: The Reciproc R25 instruments moved by RM reached significantly higher number (p<0.05) of cycles before fracture (1777.68 ± 334.2 cycles) when compared with MTwo 25/.07 instruments moved by RM (610.67 ± 126.3 cycles) or CR (432.23 ± 183.2 cycles). Conclusions: The reciprocation motion showed significantly greater cyclic fatigue resistance and the M-Wire NiTi files showed higher cyclic fatigue resistance than conventional NiTi rotary files (AU).


Subject(s)
Rotation , Dental Instruments , Endodontics , Fatigue
2.
Braz. j. oral sci ; 14(2): 122-125, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755042

ABSTRACT

Aim: To assess the effect of different torque values on cyclic fatigue resistance of K3 rotary nickel-titanium (NiTi) files. Methods: Eighty K3 files, size 25 mm, taper 0.04 were divided in 4 groups according to different torques (0.5, 1, 2 and 6 Ncm) and were submitted to a cyclic fatigue test. This test was performed with a device that allowed the file to rotate inside a stainless steel artificial curved canal, simulating the pecking motion. Files rotated until fracture occurred and time to failure was recorded in seconds with a stopwatch. Data were analyzed by ANOVA and Tukey tests (p<0.05). Results: All groups were compared and only the group of 6 N.cm showed statistically significant difference (p=0.0002). Conclusions: For #25.04 K3 files, the evaluated torques up to 2 N.cm had no influence on cyclic fatigue resistance. Using 6 N.cm torque value resulted in lower resistance to cyclic fatigue.


Subject(s)
Dental Instruments , Endodontics , Endodontics/instrumentation , Root Canal Preparation , Torque , Nickel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL